Spectrophotometer

TP-23D/25D/26D standard portable spectrophotometer

Perfect replacement for Konica Minolta CM23D CM25D CM26D

DC-23D/25D/26D reference portable spectrophotometer, ultra-high repeatability accuracy dEab≤0.01, excellent instrument station difference dEab≤0.12, industry-leading wavelength range :360-780nm, dual light source system, providing beyond the expected service life, support NetProf network correction function, 6 measuring apertures are available to easily measure samples of different shapes.

DC-23D:Repeatability dEab≤0.02;caliber 11mm、6mm

DC-25D:Repeatability dEab≤0.01;caliber 11mm、10mm、6mm、3mm
DC-26D:Repeatability dEab≤0.01;caliber 11mm、10mm、6mm、5mm、3mm、1mm3mm

Industry-leading wavelength range :360-780nm

Superior performance between stations and repeatability

The difference between the stations is 0.12, which helps to improve the color quality between manufacturers and suppliers;

Compared with the previous generation, the repeatability is 50% higher, up to 0.01;

Dual light source system to provide longer than expected service life

Xenon lamp andLED, while providing sufficient UV, visible lightEnergy and ensure tens of millions of sub-measured lifetime.

Supports NetProf network calibration

With NetProf software, the measurement performance of the instrument can be checked regularly to ensure accurate and reliable color measurement;

Through calibration, the system deviation caused by aging and wear of the instrument components can be reduced, and the accurate measurement data can bring users a more confident use experience;

6 measuring apertures are available to easily measure samples of different shapes

11mm,10mm,6mm,5mm,3mm,1*3mm Six sizes of aperture, very small objects or curved samples can be easily measured.

BCRA green plate wavelength calibration

Wavelength accuracy is automatically calibrated using a benchmark BCRA green board to ensure consistent instrumentation.

The accuracy of the indication is improved by 60%

Using a new generation of array silicon optical sensor, the light intake is increased by 65%, the spectral resolution is increased by 39%, and the accuracy is increased by 60% compared with the previous generation.

Intelligent automatic calibration

There is no need for frequent manual calibration when in use, as long as it is placed on the calibration base, the instrument will automatically calibrate the overall instrument function and accuracy according to its own state and environmental factors, ensuring that the instrument is always in a stable state and ready to be ready.

Technical parameter